The cause of the failure of the vibration disk when the power supply of the vibratory disk is connec

Release time: 2018-03-06 14:28:52

Ningbo Eagle Intelligent Technology Co., Ltd.

1. power supply is insufficient.
2. the connection between the vibration disc and the controller is broken.
3. controller fuse break.
4. coils are burned.
The gap between the 5. coils and the skeleton is too small or too large.
6. there is a part card between the coils and the skeleton.
7. vibration plate against a hard object, the top or the chassis into other equipment.
8. the electrical components are loose.
9. plugs and sockets are not in contact.
If it is only vibration, the transmission speed can not reach the requirement: check whether the electromagnetic gap is too large. The spacing between the electromagnet and armature in the normal gap corresponds to the small vibration disc in the range of 0.5MM to 1.2MM. The degree of parallelism between the iron core and the armature working face is not greater than 0.02MM. If there is no problem in the electromagnetic gap, check whether the spring is broken or not, and check whether the screw of the fastening element is loose.

 

Recommended product key words: Cixi vibratory disk Ningbo vibratory disc non standard vibration disc

 
   Previous: A new type light stainless steel lifting machine conveyer        Next: Eagle - product release this month
Home About us Products Instructions News Feedback Contact us

Copyright © Ningbo Xiongying Intelligence & Technology Co., Ltd. All Rights Reserved          Hotline: 400-0574-666
Add.: Zhangqi Town, Cixi City, Zhejiang Province, China      Record: ICP.17021542
Support: Inxun Web       中文  |  English